C.WASH™
The C.WASH is our innovative plate washer designed for automated and contactless washing of microtiter plates. It is the perfect solution for labs focusing on cell-based assays and immunoassays. The C.WASH assists labs in enhancing data quality and improving reproducibility while saving time and lowering costs.
Starting at $42,000 / €39,000
Join 1,000+ Biopharmaceutical Companies and Academic Institutions
Key Features & Benefits
Non-contact washing
Avoid carryover and cross contamination thanks to non-contact dispensing and liquid removal.
Supports multiple
plate sizes
Versatile instrument capable of gently removing liquid from any SBS format, 96- and 384- well plates.
Low residual volume
Unmatched washing efficiency with residual volumes <0.1 µl reduces the number of washing cycles required.
Fast and automated
Fully automated and stand-alone operation makes it possible to complete 1 wash cycle in 96- or 384-well plates in under 1 minute.
Product Details
Liquid removal
Dispense the plate with liquid connected to one of the 4 liquid input
channels with auto priming function. The angle dispensing allows aiming at the well walls to preserve growing cells, bound capture antibodies.
SiLA Compliant
Product
Applications
Cell-based assay
C.WASH automates all the washing and dispensing steps in a typical screening workflow, making it an essential device for drug discovery or gene editing in HTS environments.
Immunoassays
ELISAs are very sensitive immunoassays, therefore cross contamination and/or pipetting inaccuracies may result in high coefficient of variation (CV). The accurate non-contact dispensing limits both cross contamination and therefore reduces CV. Moreover, the lower residual volume after washing enables better washing efficiency and reduces the number of washes required.
Luminex® and Other Protein Assays
The C.WASH microplate washer and dispenser is a cutting-edge solution for washing assays that revolutionizes data accuracy and efficiency. By reducing background noise and variation, C.WASH ensures more quantitative data and minimizes bead loss, leading to higher signals. Its calibration-free washing enhances the reproducibility and robustness of bead-based assays.
The C.WASH magnetic plate carrier streamlines bead washing during centrifugal liquid evacuation in Luminex® and other protein assays, eliminating the laborious manual liquid removal process with automated and dedicated dispensers. This innovation expedites magnetic bead washing, reduces waste, and significantly cuts costs.
Furthermore, the multiplex assay approach facilitated by the C.WASH system maximizes data extraction, optimizes sample usage, and minimizes wash cycle expenses.
Cell in suspension
Use the C.WASH as a simple and reproducible method to wash suspension cells. Following centrifugation of the plate to pellet cells, the liquid supernatant is then evacuating using the C.WASH, resulting in washes with consistent low residual volume and with maximal cell retention as compared to manual workflow.
Plate coating
Coating wells with proteins or peptides maximizes cell adhesion in your microplates. Streamline the coating process in your laboratory using the C.WASH. Dispense the coating solution, choose your incubation time and wash and dry the plates for optimum and reproducible coating of your plates.
Featured Workflow
making it an essential device for drug discovery or gene editing in HTS environments.
Product Datasheet
license from Yantai Ausbio Laboratories
Liquid Removal | ||
---|---|---|
Plate compatibility (format) | 96,384 | |
Plate compatibility (height) | 14.4 mm | |
Residual volume | < 0.1 μL per well for all plate formats | |
Centrifugal forces | 5 to 3500 rpm (~400g) | |
Standard Dispenser (Membrane Pump & Electromechanical Valve) | ||
Dispense head | 8-needle, 16-needle | |
Liquid inputs | Auto switching (internal) for up to 4 liquid input channels | |
Dispensing accuracy & precision (standard dispenser) | < 5%CV @300µl Standard, < 3% (CV) @300 μL Precision | |
Adjustable dispense pressure | – | |
Deadvolume internal (tube volume) | 8 ml | |
Deadvolume (liquid switch/priming) | 4 ml | |
Volume range standard dispenser | 8-needle dispense head: > 10 μL 16-needle dispense head: > 5μL | |
Dispense speed – 96-well (50µl) | 16 seconds | |
Dispense speed – 384-well (25µl) | 21 seconds | |
Washing Speed | ||
Processing speed 96-well 1 wash cycle | ≤ 47 seconds | |
Processing speed 96-well 2 wash cycles | ≤ 81 seconds | |
Processing speed 384-well 1 wash cycle | ≤ 52 seconds | |
Processing speed 384-well 2 wash cycles | ≤ 85 seconds | |
Liquid Waste System | ||
Active Pump for rapid liquid removal from wash drum | ||
Misc | ||
User interface | Touchpad (included) | |
Automation | SiLA2 interface is compatible with third-party integration | |
Washing efficiency | > 99.5% after 1 wash cycle, > 99.99% after 2 wash cycles | |
Dimensions (W x D x H) | 385 x 600 x 205 mm | |
Weight | 25 kg |